Good vision requires maintenance of the transparency and proper refractive shape of the cornea. Any surface structure irregularities can lead to wavefront aberrations and scattering errors. Light scattering in the human cornea causes a reduction of visual quality. In this interview, Leopoldo Spadea of Sapienza University of Rome, Italy, discusses recent advances in refractive surgery, corneal light scatter, the benefits of canaloplasty in cataract surgery in patients with glaucoma and the upcoming European Society of Cataract Surgeons (ESCRS) congress.
Q: What are the advantages and limitations of the use of excimer lasers for irregular corneas?
Treatment of the irregular astigmatism has been posing a challenge for refractive surgeons. Historically, the alternatives for correction of irregular astigmatism were few, expectations were limited and the consequences were unpredictable anatomically and functionally. In recent years, however, advancements in laser technology have offered us better tools for facing irregular astigmatism. Ultimately, technological advances have led us to two promising customised approaches: one based on wavefront measurements and, especially, one based on corneal topography. By using these techniques, excimer laser surgery provides an accurate tool to reshape the cornea.
Q: What is the impact of corneal light scattering on vision?
Retinal image quality is degraded by scatter, diffraction and wavefront aberrations (better known as wavefront errors). Besides higher-order aberrations, changes in the transparency of the cornea could also impact on visual performance. The trasparency of the cornea is related to its highly organised structure, and when this complex configuration becomes altered, light scatter is increased, resulting in a changing luminance superimposed upon the retinal image, leading to a reduction in retinal image contrast and possible disability glare. Changes in the ultrastructure of the cornea induced by inflammation, swelling, postsurgical, wound-healing processes can lead to loss of transparency of the cornea. Haze leads to loss of corneal transparency, which can deteriorate patients’ visual function by causing glare, loss of contrast sensitivity and decrease in visual acuity. This induces increased corneal light back-scatter, which is thought to occur in many clinical conditions even with different approaches.
Q: What are the best methods of measuring corneal light scatter?
Usually, corneal light scatter is evaluated using a slit lamp biomicroscope. The Scheimpflug camera was developed according to the Scheimpflug principle. This non-invasive analysis of the anterior segment detects backscattered light in the different regions of the cornea, called a corneal densitometry map. The confocal microscope allow clinicians to compare the brightness of the haze with that of normal corneas, to identify sources of the elevated haze within the cornea, and to follow progression or regression of haze in patients. Also, a technique called optical coherence tomography has been designed to detect usually faint back-scattered light from corneal tissue.